SteamGen™ 8 Projects

In projects where power production is the primary requirement SteamGen™ 8 offers the best and most readily available HRSG technology on the market.

Tupras Refinery - Turkey

Tupras Izmir Refinery suffered badly from a boiler explosion and has decided to replace the installation with a SteamGen 8. The new HRSG will be producing steam from the exhaust of a new Siemens SGT 600, supplementary firing and fresh air firing in case of GT failure.This new installation will be supporting the refinery for decades with steam.

Project data

Client Tupras Refinery
Location Izmit, Turkey
Year of commissioning 2012
Gas turbine SGT600
Boiler type SteamGen™ 8
HP Steam capacity 100 t/h
HP Steam pressure 42 bar
HP Steam temperature 445 °C
LP Steam capacity 5.5 t/h
LP Steam pressure 6.5 bar
LP Steam temperature 205 °C

Scope of supply

  • HP steam drum
  • HP economiser 1+2
  • HP evaporator
  • HP super heater 1+2+3
  • LP steam drum
  • LP economiser
  • LP evaporator
  • LP super heater
  • Water cooled furnace
  • HP spray type desuperheaters
  • Drain and vent system incl. blow-down tank
  • HP feed water booster pumps
  • Chemical dosing units for LP and HP steam drums
  • Burner system for supplementary-/fresh air fired on natural gas
  • Internal piping and valves
  • Flue gas recirculation
  • Inlet duct
  • Outlet duct / Stack
  • Steel structures and access ways
  • Field instruments
  • Signal cables from field instruments/valves to junction boxes
  • Heat tracing incl. distribution panel
  • Transport
  • Installation
  • Commissioning & testing at site